COM-Link Category 5e Powersum
Premise Data Cables

UL TYPE CMR
300 VOLT

698

Construction

  • Conductor: 24 AWG Solid
    Bare Copper
  • Color Code Per TIA-568-C.2
    (all solid colors)

Insulation

  • Plenum: Fluoropolymer
  • Riser: Polyolefin

Jacket

  • Plenum: Flame-Retardant PVC
  • Riser: Low-Smoke, Flame-Retardant PVC

Applications

  • Gigabit Ethernet (1000Base-T)
  • Multimedia and ISDN
  • High-Speed Voice/Data Applications
  • 1.2 Gbps Ethernet
  • Broadband Video
  • Desktop Publishing

Compliances

  • ETL Verified ANSI/TIA-568-C.2
  • UL Listed Type CMR
  • UL Listed Type CMP
  • ICEA S-90-661
  • NEC Article 800
  • California State Fire Marshal
  • RoHS Compliant

Feature

  • Used in system backbones that have more stringent design requirements and are more complex than voice system backbones

Electrical Characteristics

DC Resistance (max.): 9.38

DC Resistance Unbalance (max.)
Individual Pair %:
5.0

Nominal Velocity of Propagation
Speed of Light:
Plenum: 72 Riser: 70

Characteristic Impedance (Ohms): 100 +/- 15

Propagation Delay Skew (max.) (ns/100m): 45

Part Numbers Available Putups
Jacket Color Riser Plenum 1,000' Box 1,000' Reel Bulk Reels
 BLUE 35303 35480 X X X
  GRAY 35302 35481 X X X
 WHITE 35301 35479 X X X

Physical DataRiserPlenum
Nominal Cable Diameter (inches) .510 .455
Nominal Cable Weight (lbs./1,000 ft.) 151 152
Temperature Rating (Celsius)
Installation:
Operation:
-0 to +60
-20 to +75

-0 to +60
-20 to +75

 

Transmission Throughput

 Char. ImpedanceReturn LossInsertion LossNEXTPSNEXTACRFPSACRF
Freq.(Ohms)(dB)dB /
100m
dB /
100m
dB /
100m
dB /
100m
dB /
100m
(MHz) (+/-15) (Min.) (Max.) (Min.) (Min.) (Min.) (Min.)
1 100 20 2 65.3 62.3 63.8 60.8
4 100 23 4.1 56.3 53.3 51.7 48.7
8 100 24.5 5.8 51.8 48.8 45.7 42.7
10 100 25 6.5 50.3 47.3 43.8 40.8
16 100 25 8.2 47.3 44.3 39.7 36.7
20 100 25 9.3 45.8 42.8 37.7 34.7
25 100 24.3 10.4 44.3 41.3 35.8 32.8
31.25 100 23.6 11.7 42.9 39.9 33.9 30.9
62.5 100 21.5 17 38.4 35.4 27.8 24.8
100 100 20.1 22 35.3 32.3 23.8 20.8